HVAC Removal and Replacement – 2 x Furnaces and 2 x Air Conditioning Units
What the buyer describes
The Correctional Service Canada requires the services of a qualified contractor to complete HVAC Removal and Replacement of two Furnaces and 2 Air Conditioning units in building WA01. Objectives: The qualified contract must: a.remove the existing two (2) gas fired furnaces; b.remove the existing two (2) air conditioning units; i.Dismantle, remove and dispose of the one (1) water-cooled air conditioner in the mechanical room, c.supply and install two (2) two new gas fired furnaces, and d.supply and install two (2) new air conditioning units. Deliverables: 1.Decommission and remove existing two (2) furnaces, two (2) air conditioning units, the old flue and chimney. a.The Contractor must remove and dispose of existing fresh air intake and exhaust. b.The existing flue and chimney must be decommissioned and capped by the Contractor. i.The flue side outlet will need a reducer to complete decommissioning and capping. ii. The chimney must be dismantled to the roof level and capped with a doghouse or other suitable cover. 2.Supply, install, program, commission, and verify the two (2) new furnaces and two (2) new air conditioning units to ensure full functional operation: a.Existing furnaces are currently running at 80% efficiency: •One (1) Model- “Eng Air XE 225 HB MA E S/S C” natural gas furnace, has an hourly BTU O/P of 180,000 at an elevation up to 2000ft. or 162,000 at an elevation up to 4500ft. AND •One (1) Model - “X3 160 HBMAE natural gas furnace, has an hourly BTU O/P of 128,000 at an elevation up to 2000ft. or 115,200 at an elevation up to 4500ft. Existing air conditioners are: •One (1) unit Engineered Air Model– “XE-225/C the condensing unit is Engineered Air Model CUEA61 Tagged ( CU-1 )” AND •One (1) unit – “XE-160/C the condensing unit is Engineered Air Model CUA51 Tagged (CU-2)" Existing air conditioner(s) specifications: •Location: WA01 (Finance building) Manufacture: Engineered Air, Model: CUEA61-0, Serial#: M12612 CU-1, Type: R22, Halocarbon Capacity: 8.62 Kg, Cooling Capacity: 6.1 Tons AND •Location: WA01 (Finance building) Manufacture: Engineered Air, Model: CUA-51-0, Serial#: M12612-CU-2, Type: R22, Halocarbon Capacity: 7.25 Kg, Cooling Capacity: 5.0 Tons
Most likely final-price range
| Most similar past job | Buyer | Price | Who | |
|---|---|---|---|---|
| 26-806 - HVAC Make Up Air Unit Replacement - 7 Turnbull St, Belleville ON | County of Hastings | $170,753 | low bid | Hamilton Smith Limited |
| 2024-646T - HVAC Services for Various Peel Living Apartment Buildings With Central... | Region of Peel | $1,758,076 | low bid | Ainsworth Inc. |
| C-2024-094 - HVAC Replacement - Fire Hall #2 | City of Oshawa | $843,800 | low bid | Comfort Care Inc. |
| C-2024-103 - HVAC Replacement - Civic Dome | City of Oshawa | $512,868 | low bid | Bird Infrastructure Ltd. |
| 2025-101-CQ - Lindsay Recreation Complex HVAC Replacement | City of Kawartha Lakes | $1,034,300 | low bid | Adamson and Dobbin Ltd. |
| 25-06 - PASA Main Rink HVAC Replacement | City of Sarnia | $2,410,290 | low bid | Innovative Construction Services Inc. |
Built from keyword-matched historical jobs: "awarded" rows are executed contract values, "low bid" rows are unofficial bid-opening totals. Similar scope is not identical scope — treat this as the bracket to sanity-check your own takeoff against, never as the estimate itself. Trade-wide, roofing low bids run $367,559 median across 154 openings — full history on the board.
New roofing tenders, straight to your inbox — free.
At most one email a day, only when something matching lands. Unsubscribe in one click.