Plumbing(PS)
5050 SHEPPARD AVE E, TorontoPermit details
- Application
- 26 256859 PLB rev 00
- Address
- 5050 SHEPPARD AVE E, Toronto (M1S)
full property record — every permit and signal at this address
- Work
- Building Permit Related(PS)
- Structure
- Transit Station,Subway, Bus Terminal
- Status
- Application Acceptable
- Applied
- 2026-10-19
- Issued
- —
- Declared value
- —
- Current use
- Bus Garage
- Proposed use
- Bus Garage
- Builder
- Owner-filed
Scope of work (as filed)
Plumbing - Proposal to add electronic level monitoring to one (1) existing 2,900 L volume Transformer Room Spill Tank (Tank MA1). Decommission and remove one (1) existing 2,325 L volume Flammable Storage Room Spill Tank (Tank ID MA2), piping, and associated appurtenances. Existing Veeder-Root TLS-450 console to remain. Make arrangements with TTC for re-configuration / programming of the existing Veeder-Root console. Existing concrete paving and granular fill is to be removed. Provide concrete paving and grading as required for the area to drain to the nearest catch basin(s). Test and recommission all new and existing piping, power and Veeder-Root components of the existing 2,900 L Transformer Spill Room Tank. Demolish existing bollards and install new protective bollards in accordance with the Contract Drawings. Existing underground Tanks 310 and 311 shall be protected during construction. Make good walls and floors where pipe and conduit penetrations have been removed. Firestop openings in fire rated assemblies¿. Resurface affected pavement (affected by removal of Flammable Storage Room Spill Tank (Tank ID MA2) and addition of direct buried conduit for electronic level monitoring to Transformer Room Spill Tank (Tank ID MA1)) in accordance with Contract Drawings.
Inferred opportunity scopes
DemolitionDerived by rules from the permit text — an opportunity signal, not a statement that these packages are open or being bid.
Same application (1)
| Permit | Applied | Status |
|---|---|---|
| Building Additions/Alterations rev 00 Other(BA) |
2026-10-19 | Application Acceptable |
Revisions and plumbing/mechanical/drain permits filed under the same application number.
Is this project worth chasing?
Likely scopes · competitive activity · lifecycle stage · opportunity score · fit for your trade.
Analyze this project →Planning something similar?
If you're an owner or tenant planning comparable work, we'll tell you what it should cost — read from records like this one — and introduce insured contractors with a track record on it.